ix

 

USE CODE DESCRIPTIONS

 

CODE    PAGE     DESCRIPTION

 

AA01      8     Day nurseries with a maximum permitted occupancy of 6 or more

                but fewer than 50 persons.

 

 

AA02     11     Daycare centers with a maximum permitted occupancy of 6 or more

                But fewer than 50 persons.

 

 

AA03     14     Camps with a maximum permitted occupancy of fewer than 50

                children of school age.

 

 

AA04     17     Educational building serving six or more but fewer than 50

                students from kindergarten through grade 12 and also means and

                includes an educational building serving six or more but fewer

                than 50 students in some, but not all of the grades from

                kindergarten to grade 12, inclusive.

 

 

AB01      9     Day nurseries with a maximum permitted occupancy of 50 or more

                But fewer than 100 persons

 

 

AB02     12     Daycare centers with a maximum permitted occupancy of 50 or more

                but fewer than 100 persons.

 

 

AB03     15     Camps with a maximum permitted occupancy of 50 or more but fewer

                than 100 children of school age.

 

 

AC01     21     Hotels, motels, and retreat lodging facilities of two or three

    stories and under 25 rooms, with any interior exit-ways.

 

 

AC02     31     Rooming and boarding homes of one story.

 

 

AC03     47     Eating and/or drinking establishments with a maximum permitted

                occupancy of fewer than 50 persons in which alcoholic beverages

                may be consumed.

 

 

AC04     20     School dormitories of use group R-2 of one story.

 

 

AC05     34     Guest houses, as defined in N.J.A.C. 5:70-1.5, regardless of

                number of stories.

 

 

 

x

CODE    PAGE     DESCRIPTION

 

 

AC07     13     Recreation centers and multipurpose rooms used for adult daycare

                with a maximum permitted occupancy of six or more but fewer than

                50 persons.

 

 

AD01      1     All buildings or structures used for the service of motor

                vehicles, including aircraft and marine motor craft.

 

 

AD02      2     All buildings or locations where flammable and/or combustible

                fuels are stored and dispensed to motor vehicles, including

                aircraft and marine motor craft.

 

 

AD03     35     Halfway houses, group homes, community residences, residential

                child care facilities, residential health care facilities,

                alcohol and drug treatment centers, youth hostels, homeless

                shelters and other similar facilities with a maximum permitted

                occupancy of fewer than 50 persons.

 

 

AD04     80     Buildings used for dry cleaning purposes using nonflammable

                cleaning solvents.

 

 

AD05     16     Camps with a maximum permitted occupancy of 100 or more

                children of school age.

 

 

AD06     55     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 50 or more but fewer than 100 persons.

 

 

AD07     63     Funeral homes, funeral parlors and mortuaries providing access

                to the public with a maximum permitted occupancy of 50 or more

                but fewer than 100 persons.

 

 

AE01     10     Day nurseries with a maximum permitted occupancy of 100 persons

                or more.

 

 

AE02     13     Daycare centers with a maximum permitted occupancy of 100

                persons or more.

 

 

 

 

 

 

 

xi

 

CODE    PAGE     DESCRIPTION

 

AE03     18     Educational building serving 50 or more students from

               kindergarten through grade 12 and also means and includes an

                educational building serving 50 or more students in some, but

                not all of the grades from kindergarten to grade 12, inclusive.

 

 

AE04     19     After-school programs, in buildings or portions thereof of other

                than Use Group E, accommodating six or more buy fewer than 50

                children of school age.

 

 

AF01      2     All buildings or locations where flammable and/or combustible

                fuels are stored and dispensed and used for the service of

                motor vehicles, including aircraft and marine motor craft.

 

 

AF02     22     Hotels, motels, and retreat lodging facilities of two or three

    stories and 25 or more but fewer than 50 rooms with any interior

    exit-ways.

 

 

AF03     36     Halfway houses, group homes, community residences, residential

                child care facilities, residential health care facilities,

                alcohol and drug treatment centers, youth hostels, homeless

                shelters and other similar facilities with a maximum permitted

                occupancy of 50 or more but fewer than 100 persons.

 

 

AF04     32     Rooming and boarding homes of two or three stories.

 

 

AF05     20     School dormitories of use group R-2 of two or three stories.

 

 

AG01     48     Eating and/or drinking establishments with a maximum permitted

                occupancy of 50 or more but fewer than 100 persons.

 

 

AG02     23     Hotels, motels, and retreat lodging facilities of two or three

    stories and 50 or more but fewer than 100 rooms, with any

    interior exit-ways.

 

 

AG03    119     Above ground aggregate storage of more than 660 gallons but less

                than 5000 gallons of Class II or IIIA combustible liquids

                (except for heating purposes).

 

 

AG04     19     After-school programs, in buildings or portions thereof of other

                than Use Group E, accommodating 50 or more children of school       

                age.

 

 

xii

 

CODE    PAGE     DESCRIPTION

 

AH01     33     Rooming and boarding homes of four or more stories.

 

AH02     37     Halfway houses, group homes, community residences, residential

                child care facilities, residential health care facilities,

                alcohol and drug treatment centers, youth hostels, homeless

                shelters and other similar facilities with a maximum permitted

                occupancy of 100 persons or more.

 

 

AH03     20     School dormitories of use group R-2 of four or more stories.

 

 

AH04     25     Hotels, motels, and retreat lodging facilities of four or five

    stories and having fewer than 50 rooms, with any interior exit-

    ways.

 

AI01     24     Hotels, motels, and retreat lodging facilities of two or three

    stories and 100 rooms or more, with any interior exit-ways.

 

 

AI02     79     Hardware stores and home improvement centers of 3,000 or more

                but less than 12,000 square feet of gross floor area.

 

 

AI03     26     Hotels, motels, and retreat lodging facilities of four or five

    stories and which have 50 or more but fewer than 100 rooms, with

    any interior exit-ways.

 

 

AJ02    119     Above ground aggregate storage of 5,000 gallons or more, but

                less than 50,000 gallons of Class II or IIIA combustible

                liquids, or above ground aggregate storage of more than 660

                gallons but less than 10,000 gallons of Class I flammable

                liquids.

 

 

BA01    146     Welding or cutting operations on a regular basis not using

                Flammable gases in buildings or structures under 10,000 square

                feet.

 

 

BB01     63     Funeral homes, funeral parlors and mortuaries providing access

                to the public with a maximum permitted occupancy of 100 or more

                but fewer than 200 persons.

 

 

BB02     56     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 100 or more but fewer than 200 persons.

 

 

 

xiii

 

CODE    PAGE     DESCRIPTION

 

BB03    147     Welding or cutting operations on a regular basis not using

                flammable gases in buildings or structures of 10,000 or more but

                less than 50,000 square feet.

 

BB04    152     Transfer from one container to another of liquefied petroleum

                gas or liquefied natural gas at any location, other than motor

                vehicle or marine motor craft service stations, not registered

                for storage and use.

 

BB05      3     Spraying or dipping operations involving paint, varnish,

                lacquer, stain, or other flammable or combustible liquids in all

                approved areas of less than 100 square feet.

 

 

BC01     57     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 200 or more but fewer than 500 persons.

 

 

BC02     63     Funeral homes, funeral parlors and mortuaries providing access

                to the public with a maximum permitted occupancy of 200 or more

                but fewer than 500 persons.

 

 

BD01     65     Motion picture theaters or theaters incorporating a legitimate,

                regular or thrust stage, without any scenery or prop storage

                areas behind a proscenium arch, with a maximum permitted

                occupancy of fewer than 100 persons.

 

 

BD02    111     The manufacture, processing or blending of less than 1,000

                gallons of Class I flammable liquid, or less than 10,000 gallons

                of Class II or IIIA combustible liquids in any one working day.

                Blending must be in a vessel, not in piping at or near the point

                of delivery.

 

 

BD03    148     Welding or cutting operations on a regular basis not using

                flammable gases in buildings or structures of 50,000 square feet

                or more.

 

 

BD04    108     Storage of fireworks, explosives or blasting agents in a type 4

                magazine.

 

 

BD05     49     Eating and/or drinking establishments with a maximum permitted

                occupancy of 100 or more but fewer than 200 persons.

 

 

 

xiv

 

CODE    PAGE     DESCRIPTION

 

BD07      4     Spraying or dipping operations involving paint, varnish,

                lacquer, stain, or other flammable or combustible liquids in all

                approved areas of 100 or more but less than 250 square feet.

 

 

BD08    149     Welding or cutting operations using flammable gases on a regular

                basis in buildings or structures under 10,000 square feet.

 

 

BE01     27     Hotels, motels, and retreat lodging facilities of four or five

    stories, and which have 100 rooms or more with any interior

    exit-ways.

 

 

BE02    150     Welding or cutting operations using flammable gases on a regular

                basis in buildings or structures of 10,000 square feet or more

                but less than 50,000 square feet.

 

 

BE03     58     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 500 or more but fewer than 1,000 persons.

 

 

BE04     63     Funeral homes, funeral parlors and mortuaries providing access

                to the public with a maximum permitted occupancy of 500 or more

                persons.

 

 

BF01     43     Prisons and other facilities of 6 or more but fewer than 50 beds

                where residents, occupants, or inmates are kept under restraint.

 

 

BF02     66     Motion picture theaters or theaters incorporating a legitimate,

                regular or thrust stage, without any scenery or prop storage

                areas behind a proscenium arch, with a maximum permitted

                occupancy of 100 or more but fewer than 200 persons.

 

 

BF03     81     Retail stores and other mercantile uses of more than 12,000

                square feet but less than 24,000 square feet in gross floor

                area.

 

 

BF04     28     Hotels, motels, and retreat lodging facilities which exceed five

    stories, and have under 50 rooms with any interior exit-ways.

 

 

 

 

 

 

xv

 

CODE    PAGE     DESCRIPTION

BF07     90     Equipment, processes, and operations involving dust which, if

                mixed with air, becomes explosive including but not limited to

                grain bleachers or elevators; flour, starch or feed mills; malt

                houses; wood flour manufacturing plants; or plants that

                pulverize aluminum, coal, cocoa, magnesium, spices, or sugar in

                all buildings or structures under 50,000 square feet.

 

 

BF08     94     Crop ripening or coloring processes in all buildings or

                structures under 50,000 square feet.

 

 

BF09     87     Lumber yards and/or woodworking plants in which more than

                100,000 but less than 250,000 board feet of lumber is to be

                stored.

 

BF10     95     Tire recapping or rebuilding plants in buildings or structures

                under 50,000 square feet.

 

 

BF11     98     Manufacturing of articles of cellulose nitrate plastics

                including the use of cellulose nitrate plastics in the

                manufacture or assembly of other articles in all buildings or

                structures under 50,000 square feet.

 

 

BF12    105     The manufacture of matches in all buildings or structures under

                50,000 square feet.

 

 

BF13    107     The manufacture of fire-works, explosives or blasting agents in

                all buildings or structures under 50,000 square feet.

 

 

BF14    112     The manufacture, processing or blending of more than 1,000 but

                less than 10,000 gallons of Class I flammable liquids in any one

                working day. Blending must be in a vessel, not in piping at or

                near the point of delivery.

 

 

BF16    122     Storage of more than 2,500 cubic feet gross volume of

                combustible empty assembled packing cases, boxes, barrels,

                pallets, or similar containers in a building not classified as a

                warehouse or factory.

 

 

BF17    123     Storage of more than 2,500 cubic feet gross volume of rubber

                tires, baled cotton, rubber, cork or other similarly combustible

                material in a building not classified as a warehouse or factory.

 

 

BF18    106     Storage of matches with more than 25 but fewer than 50 cases in

                the aggregate.

 

 

xvi

 

CODE    PAGE     DESCRIPTION

 

BF19    109     Storage of fireworks, explosives or blasting agents in a Type UG

                magazine.

 

 

BF20    120     Above ground aggregate storage of more than 50,000 but less than

                1,000,000 gallons of Class II or IIIA combustible liquids.

 

 

BF21    127     Factories and other industrial uses of Use Group F-1, not

                otherwise classified, of 12,000 or more but less than 24,000

                square feet of gross floor area.

 

 

BF22    137     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, not otherwise

                classified, of 12,000 or more, but less than 24,000 square feet

                in gross floor area.

 

 

BF23    153     Any installation of liquefied petroleum gas or liquefied natural

                gas utilizing storage containers of over 1,000 gallons

                individual water capacity or with an aggregate water capacity

                exceeding 2,000, but not more than 4,000 gallons.

 

 

BG01    155     Any high-rise structure of 7 or more but fewer than 10 stories.

 

 

BG02     43     Prisons and other facilities of 50 or more but fewer than 100

                beds where residents, occupants, or inmates are kept under

                restraint.

 

 

BG03     38     Free-standing institutional and similar facilities including but

                not limited to outpatient surgery facilities, renal dialysis

                facilities, abortion clinics and birthing centers, in buildings

                of less than 10,000 square feet.

 

 

BG04     67     Motion picture theaters and theaters incorporating a legitimate,

                regular or thrust stage, without any scenery or prop storage

                areas behind a proscenium arch, with a maximum permitted

                occupancy of 200 or more but fewer than 400 persons.

 

 

BG05     50     Eating and/or drinking establishments with a maximum permitted

                occupancy of 200 or more but fewer than 300 persons.

 

 

BG06     82     Retail stores and other mercantile uses of 24,000 or more but

                less than 48,000 square feet in gross floor area.

 

 

xvii

 

CODE    PAGE     DESCRIPTION

BG07     29     Hotels, motels, and retreat lodging facilities, which exceed                  five stories, and which have 50 or more but fewer than 100                  rooms with any interior exit-ways.

 

 

BG08     59     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 1,000 or more but fewer than 3,000

                persons.

 

 

BG09     69     Transportation terminals with a maximum permitted occupancy of

                100 or more persons.

 

 

BG10      5     Spraying or dipping operations involving paint, varnish,

                lacquer, stain, or other flammable or combustible liquids in all

                approved areas of 250 or more but less than 500 square feet.

 

 

BG11     91     Equipment, processes, and operation which involve dust which, if

                mixed with air, becomes explosive including but not limited to

                grain bleachers or elevators; flour, starch or feed mills; malt

                houses; wood flour manufacturing plants; or plants that

                pulverize aluminum, coal, cocoa, magnesium, spices, or sugar in

                all buildings or structures of 50,000 or more but less than

                100,000 square feet.

 

 

BG12     94     Crop ripening or coloring processes in all buildings or

                structures of 50,000 square feet or more but less than 100,000

                square feet.

 

 

BG13     88     Lumber yards and/or wood-working plants in which 250,000 or more

                but less than 500,000 board feet of lumber is to be stored.

 

 

BG14     95     Tire recapping or rebuilding plants in buildings or structures

                of 50,000 square feet or more but less than 100,000 square feet.

 

 

BG15     97     Organic coating manufacturing operations making one gallon or

                more of an organic coating in a working day.

 

 

BG16     99     Manufacturing of articles of cellulose nitrate plastics

                including the use of cellulose nitrate plastics in the

                manufacture or assembly of other articles in all buildings or

                structures of 50,000 or more but less than 100,000 square feet.

 

 

 

 

xviii

 

CODE    PAGE     DESCRIPTION

 

BG17    102     Processing, handling or use of 100 or more but less than 500

                cubic feet of loose combustible vegetable or animal fibers,

                including but not limited to readily ignitable and free burning

                fibers such as cotton, sisal, heneguer, ixtle, jute, hemp, tow,

                cocoa fiber, oakum, baled waste, baled waste paper, kapok, hay,

                straw, Spanish moss, excelsior, certain synthetic fibers, and

                cloth in the form of scraps and clippings.

 

 

BG18    105     The manufacture of matches in all buildings or structures of

                50,000 or more but less than 100,000 square feet.

 

 

BG19    107     The manufacture of fireworks, explosives or blasting agents in

                all buildings or structures of 50,000 or more but less than

                100,000 square feet.

 

 

BG23    101     Storage of cellulose nitrate motion picture film or cellulose

                nitrate (pyroxylin) plastics in quantities which exceed 25

                pounds.

 

BG24    124     Storage of 100 or more but less than 500 cubic feet of loose

                combustible vegetable or animal fibers.

 

 

BG25    106     Storage of matches with 50 or more cases in the aggregate.

 

 

BG26    110     Storage of fireworks, explosives or blasting agents in a Type 1

                magazine.

 

 

 

BG27    120     Above ground storage of 10,000 or more but less than 100,000

                gallons of Class I flammable liquids.

 

 

BG30    129     Factories and other industrial uses of Use Group F-1, not

                otherwise classified, of 24,000 or more but less than 50,000

                square feet of gross floor area.

 

 

BG31    138     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, not otherwise

                classified, of 24,000 or more, but less than 50,000 square feet

                in gross floor area.

 

 

 

 

xix

 

CODE    PAGE     DESCRIPTION

 

BH01     44     Prisons and other facilities of 100 or more but fewer than 200

                beds where residents, occupants, or inmates are kept under

                restraint.

 

 

BH02     30     Hotels, motels, and retreat lodging facilities, which exceed                 five stories, and which have 100 rooms or more with any interior

    exit-ways.

 

 

BH03    113     The manufacture, processing or blending of more than 10,000 but

                less than 100,000 gallons of Class II and/or IIIA combustible

                liquids in any one working day.  Blending must be in a vessel,

                not in piping at or near the point of delivery.

 

 

BH04    154     Any installation of liquefied petroleum gas or liquefied natural

                gas utilizing storage containers of over 4.000 gallons aggregate

                water capacity.

 

 

BH05     68     Motion picture theaters and theaters incorporating a legitimate,

                regular or thrust stage, without any scenery or prop storage

                areas behind a proscenium arch, with a maximum permitted

                occupancy of 400 or more but fewer than 700 persons.

 

BI01     44     Prisons and other facilities of 200 or more but fewer than 300               

    beds where residents, occupants, or inmates are kept under

                restraint.

 

 

BI02    130     Factories and other industrial uses of Use Group F-1, not

                otherwise classified, of 50,000 or more but less than 100,000

                square feet of gross floor area.

 

BI03    139     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, not otherwise

                classified, of 50,000 or more, but less than 100,000 square

                feet in gross floor area.

 

 

BI04     69     Motion picture theaters and theaters incorporating a legitimate,

                regular or thrust stage, without any scenery or prop storage

                areas behind a proscenium arch, with a maximum permitted

                occupancy of 700 or more but fewer than 1,000 persons.

 

 

BJ01    155     Any high-rise structure of 10 or more but fewer than 20 stories.

 

 

 

 

 

xx

CODE    PAGE     DESCRIPTION

 

BJ02     39     Free-standing institutional and similar facilities including but

                not limited to outpatient surgery facilities, renal dialysis

                facilities, abortion clinics and birthing centers, in buildings

                of 10,000 square feet or more.

 

 

BJ04     83     Retail stores and other mercantile uses of 48,000 square feet or

                more but less than 100,000 square feet in gross floor area.

 

 

BJ05     76     Stadiums, race tracks and other similar exterior places of

                amusement with enclosed interior spaces, with a maximum

                permitted occupancy of fewer than 5,000 persons.

 

 

BJ06      7     Spraying or dipping operations involving paint, varnish,

                lacquer, stain, or other flammable or combustible liquids in all

                approved areas of 1000 square feet or more.

 

 

BJ07     93     Equipment, processes, and operation which involve dust which, if

                mixed with air, becomes explosive including but not limited to

                grain bleachers or elevators; flour, starch or feed mills; malt

                houses; wood flour manufacturing plants; or plants that

                pulverize aluminum, coal, cocoa, magnesium, spices, or sugar in

                all buildings or structures of 100,000 square feet or more.

 

 

BJ08     94     Crop ripening or coloring processes in all buildings or

                structures of 100,000 square feet or more.

 

 

BJ09     89     Lumber yards and/or wood-working plants in which 500,000 board

                feet or more of lumber is to be stored.

 

 

BJ10     96     Tire recapping or rebuilding plants in buildings or structures

                of 100,000 square feet or more.

 

 

BJ11    100     Manufacturing of articles of cellulose nitrate plastics

                including the use of cellulose nitrate plastics in the

                manufacture or assembly of other articles in all buildings or

                structures of 100,000 square feet or more.

 

 

BJ12    103     Processing, handling or use of 500 or more but less than 2,500

                cubic feet of loose combustible vegetable or animal fibers,

                including but not limited to readily ignitable and free burning

                fibers such as cotton, sisal, heneguer, ixtle, jute, hemp, tow,

                cocoa fiber, oakum, baled waste, baled waste paper, kapok, hay,

                straw, Spanish moss, excelsior, certain synthetic fibers, and

                cloth in the form of scraps and clippings.

 

xxi

CODE    PAGE     DESCRIPTION

 

BJ13    105     The manufacture of matches in all buildings or structures of

                100,000 square feet or more.

 

 

BJ14    107     The manufacture of fire-works, explosives or blasting agents in

                all buildings or structures of 100,000 square feet or more.

 

 

BJ15    114     The manufacture, processing or blending of more than 10,000 but

                less than 100,000 gallons of Class I flammable liquids in any

                one working day.  Blending must be in a vessel, not in piping at

                or near the point of delivery.

 

 

BJ19    125     Storage of 500 or more but less than 2,500 cubic feet of loose

                combustible vegetable or animal fibers.

 

 

BJ20    120     Above ground aggregate storage of 1,000,000 or more but less

                than 5,000,000 gallons of Class II or IIIA combustible liquids,

                or above ground storage of 100,000 or more but less than

                1,000,000 gallons of Class I flammable liquids.

 

 

BJ21    158     Buildings with atrium spaces three or more stories in height in

                buildings which exceed 12,000 square feet in gross floor area.

 

 

BK01    156     Any high-rise structure of 20 or more but fewer than 30 stories.

 

 

BK02    104     Processing, handling or use of 2,500 cubic feet or more of loose                

    combustible vegetable or animal fibers, including but not

                limited to, readily ignitable and free burning fibers such as

                cotton, sisal, heneguer, ixtle, jute, hemp, tow, cocoa fiber,

                oakum, baled waste, baled waste paper, kapok, hay, straw,

                Spanish moss, excelsior, certain synthetic fibers, and cloth in

                the form of scraps and clippings.

 

 

BK03    126     Storage of 2,500 cubic feet or more of loose combustible

                vegetable or animal fibers.

 

 

BK04    121     Above ground aggregate storage of 5,000,000 gallons or more of

                Class II and/or IIIA combustible liquids.

 

 

BK05    131     Factories and other industrial uses of use group F-1, not

                otherwise classified, of 100,000 or more, but less than 150,000

                square feet, in gross floor area.

 

 

 

xxii

CODE    PAGE     DESCRIPTION

 

BK06    140     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, not otherwise

                classified, of 100,000 or more, but less than 150,000 square

                feet, in gross floor area.

 

 

BK07     70     Motion picture theaters and theaters incorporating a legitimate,

                regular or thrust stage, without any scenery or prop storage

                areas behind a proscenium arch, with a maximum permitted

                occupancy of 1,000 or more persons.

 

 

BL01    156     Any high-rise structure of 30 stories or more.

 

 

BL02    115     The manufacture, processing or blending of more than 100,000 but

                less than 1,000,000 gallons of Class II and/or IIIA combustible

                liquids in any one working day. Blending must be in a vessel,

                not in piping at or near the point of delivery.

 

 

BL03    132     Factories and other industrial uses of Use Group F-1, not

                otherwise classified, of 150,000 or more but less than 200,000

                square feet of gross floor area.

 

 

BL04    141     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, not otherwise

                classified, of 150,000 or more, but less than 200,000 square

                feet in gross floor area.

 

 

BL05     84     Retail stores and other mercantile uses of 100,000 square feet               

    or more but less than 200,000 square feet in gross floor area.

 

 

BL06     45     Prisons and other facilities of 300 or more but fewer than 1,000

                beds where residents, occupants, or inmates are kept under

                restraint.

 

 

BM01     77     Stadiums, race tracks and other similar exterior places of

                amusement with enclosed interior spaces, with a maximum

                permitted occupancy of 5,000 or more but fewer than 10,000

                persons.

 

 

BM02    116     The manufacture, processing or blending of more than 100,000 but

                less than 1,000,000 gallons of Class I flammable liquids in any

                one working day. Blending must be in a vessel, not in piping at

                or near the point of delivery.

 

 

 

xxiii

CODE    PAGE     DESCRIPTION

 

BM03    121     Above ground aggregate storage of 1,000,000 gallons or more but

                less than 5,000,000 gallons of Class I flammable liquids.

 

 

BM04    133     Factories and other industrial uses of Use Group F-1, of 200,000

                square feet or more, but less than 350,000 square feet in gross

                floor area.

 

 

BM05    142     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, of 200,000

                square feet or more, but less than 350,000 square feet in gross

                floor area.

 

 

BM06     45     Prisons and other facilities of 1,000 or more but fewer than

                2,000 beds where residents, occupants, or inmates are kept under

                restraint.

 

 

BN01    117     The manufacture, processing or blending of 1,000,000 gallons or

                more of Class I, II and/or IIIA flammable or combustible liquids

                in any one working day.  Blending must be in a vessel, not in

                piping at or near the point of delivery.

 

 

BN02    121     Above ground aggregate storage of 5,000,000 gallons or more of

                Class I flammable liquids.

 

 

BN03     85     Retail stores and other mercantile uses of 200,000 square feet

                or more but less than 400,000 square feet in gross floor area.

 

 

BN04    134     Factories and other industrial uses of Use Group F-1 of 350,000

                square feet or more, but less than 500,000 square feet in gross

                floor area.

 

 

BN05    143     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, of 350,000

                square feet or more, but less than 500,000 square feet in gross

                floor area.

 

 

BN06     46     Prisons and other facilities of 2,000 or more but fewer than

                3,000 beds where residents, occupants, or inmates are kept under

                restraint.

 

 

BO01     78     Stadiums, race tracks and other similar exterior places of

                amusement with enclosed interior spaces, with a maximum

                permitted occupancy of 10,000 or more persons.

 

xxiv

CODE    PAGE     DESCRIPTION

 

BO02    118     Refining of flammable and combustible liquids.

 

 

BO03     86     Retail stores and other mercantile uses of 400,000 square feet

                or more in gross floor area.

 

 

BO04    135     Factories and other industrial uses of Use Group F-1 of 500,000

                square feet or more, but less than 750,000 square feet in gross

                floor area.

 

 

BO05    144     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, of 500,000

                square feet or more, but less than 750,000 square feet in gross

                floor area.

 

 

BO06     46     Prisons and other facilities of 3,000 or more where residents,

                occupants, or inmates are kept under restraint.

 

 

BP01      6     Spraying or dipping operations involving paint, varnish,

                lacquer, stain, or other flammable or combustible liquids in all

                approved areas of 500 or more but less than 1000 square feet.

 

 

BP02    151     Welding or cutting operations using flammable gases on a regular

                basis in buildings or structures of 50,000 square feet or more.

 

 

BQ01    136     Factories and other industrial uses of Use Group F-1 of 750,000

                square feet or more in gross floor area.

 

 

BQ02    145     Warehouses, storehouses and freight depots, used for the storage

                and handling of ordinary combustible materials, of 750,000

                square feet or more in gross floor area.

 

 

CA01     71     Theaters incorporating a legitimate, regular or thrust stage

                having any scenery or prop storage area behind a proscenium arch

                and having a maximum permitted occupancy of fewer than 100

                persons.

 

 

CB01     72     Theaters incorporating a legitimate, regular or thrust stage

                having any scenery or prop storage area behind a proscenium arch

                and having a maximum permitted occupancy of 100 or more but

                fewer than 200 persons.

 

 

 

 

xxv

CODE    PAGE     DESCRIPTION

 

CC02     40     Institutional and similar facilities including hospitals and

                long term care facilities which house people suffering from

                physical limitation due to age, health, or handicaps which have

                fewer than 100 beds.

 

 

CC03     51     Eating and/or drinking establishments with a maximum permitted

                occupancy of 300 or more but fewer than 500 persons.

 

 

CD01     73     Theaters incorporating a legitimate, regular or thrust stage

                having any scenery or prop storage area behind a proscenium arch

                and having a maximum permitted occupancy of 200 or more but

                fewer than 300 persons.

 

 

CD02     41     Institutional and similar facilities including those hospitals

                and long term care facilities which house people suffering from

                physical limitation due to age. health, or handicaps which have

                100 beds or more but fewer than 200 beds.

 

 

CE01     74     Theaters incorporating a legitimate, regular or thrust stage

                having any scenery or prop storage area behind a proscenium arch

                and having a maximum permitted occupancy of 300 or more.

 

 

CE03     42     Institutional and similar facilities including those hospitals

                and long term care facilities which house people suffering from

                physical limitation due to age, health, or handicaps which have

                200 beds or more.

           

 

CF01     75     Places of amusement which are designed to disorient the

occupant, reduce vision, present barriers or otherwise impede the free flow of traffic such as haunted houses, fun houses, tunnels of love and similar uses.

               

               

   

CG01     60     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 3,000 or more but fewer than 8,000

                persons.

 

 

 

 

 

 

 

 

 

xxvi

CODE    PAGE     DESCRIPTION

 

CG03     52     Eating and/or drinking establishments with a maximum permitted

                occupancy of 500 or more but fewer than 750 persons.

 

 

CH01     53     Eating and/or drinking establishments with a maximum permitted

                occupancy of 750 or more but fewer than 1000 persons.

 

 

CI01     54     Eating and/or drinking establishments with a maximum permitted

                occupancy of 1000 or more persons.

 

 

CI02     61     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 8,000 or more but fewer than 12,000

                persons.

 

 

DA01    159     Covered mall buildings with a mall portion of 12,000 or more but

                less than 50,000 square feet.

 

 

DB01    159     Covered mall, mall area of 50,000 or more but less than 100,000

                square feet.

 

 

DB02     62     Recreation centers, multipurpose rooms, lecture halls, art

                galleries, exhibition halls and similar uses where persons

                assemble other than for religious services with a maximum

                permitted occupancy of 12,000 or more persons.

 

DC01    160     Covered mall buildings with a mall portion of 100,000 square

                feet or more.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xxvii

 

FEES

Code

Group       Pre 10/91        10/91        11/96        10/1/03

 

Aa          $   58.00      $   70.00     $   70.00     $   84.00

Ab          $   86.00      $  103.00    $  103.00   $  124.00

Ac          $   92.00      $  110.00    $  110.00   $  132.00

Ad          $  104.00      $  123.00    $  123.00   $  148.00

Ae          $  115.00      $  138.00    $  138.00   $  166.00

Af          $  138.00      $  166.00    $  166.00   $  199.00

Ag          $  173.00      $  208.00    $  208.00   $  250.00

Ah          $  207.00      $  248.00    $  248.00   $  298.00

Ai          $  276.00      $  331.00    $  331.00   $  397.00

Aj          $  345.00      $  414.00    $  414.00   $  497.00

 

Ba          $   92.00      $  110.00    $  110.00   $  132.00

Bb          $  173.00      $  208.00    $  208.00   $  250.00

Bc          $  276.00      $  331.00    $  331.00   $  397.00

Bd          $  345.00      $  414.00    $  414.00   $  497.00

Be          $  403.00      $  484.00    $  484.00   $  581.00

Bf          $  518.00      $  622.00    $  591.00   $  709.00

Bg          $  552.00      $  662.00    $  629.00   $  755.00

Bh          $  690.00      $  828.00    $  787.00   $  944.00

Bi          $  828.00      $  997.00    $  947.00   $1,136.00

Bj          $  863.00      $1,036.00    $  984.00   $1,181.00

Bk          $1,035.00      $1,242.00    $1,180.00   $1,416.00

Bl          $1,208.00      $1,450.00    $1,378.00   $1,654.00

Bm          $1,380.00      $1,656.00    $1,537.00   $1,844.00

Bn          $1,725.00      $2,070.00    $1,967.00   $2,360.00

Bo          $2,070.00      $2,484.00    $2,360.00   $2,832.00

Bp               n/a            n/a     $  828.00   $  994.00

Bq               n/a            n/a          n/a    $3,088.00

 

Ca          $  690.00      $  828.00    $  787.00   $  944.00

Cb          $  828.00      $  994.00    $  944.00   $1,133.00

Cc          $  897.00      $1,076.00    $1,022.00   $1,226.00

Cd          $  966.00      $1,159.00    $1,101.00   $1,321.00

Ce          $1,104.00      $1,325.00    $1,259.00   $1,511.00

Cf          $1,208.00      $1,450.00    $  450.00   $  540.00

Cg          $1,380.00      $1,656.00    $1,573.00   $1,888.00

Ch                n/a      $2,080.00    $1,976.00   $2,371.00

Ci                n/a      $2,500.00    $2,375.00   $2,850.00

 

 

 

xxviii

 

FEES

Code

Group       Pre 10/91        10/91        11/96        10/1/03

 

 

Da          $2,070.00      $1,650.00    $1,568.00   $1,882.00

Db                n/a       $2,500.00    $2,375.00   $2,850.00

Dc               n/a       $3,250.00    $3,088.00   $3,706.00

 

 

 

 

June, 2008

CodeDescripts.doc